Loading...






Large vent openings to increase steam/heat penetration rate.

Standard Sterilizing Autoclave Cylinders


Standard Sterilizing Cylinders


CBC's Standard Autoclave Sterilizing Cylinders for water, bedding, cages and other components used in germ-free, gnotobiotic animal research.

Supply tray with backstop to help prevent items from falling off tray.


Standard Sterilizing Cylinder


• Constructed out of stainless steel

• Glass bead finish

• Four carrying handles

CBC Standard Sterilizing Cylinders have large vent openings to increase steam/heat penetration rate.


Unwrapped Standard Sterilizing Cylinders showing large vent openings to increase steam/heat penetration rate.

Above: Unwrapped Standard Sterilizing Cylinders showing large vent openings. (l) 12" dia. x 24" long Cylinder. (r) 18" dia. x 30" long Cylinder.


Autoclave Sterilizing Standard Cylinder Features:


  • 3 layers of DW4 filter media
  • Stainless steel clamp
  • Sterilizing cylinder is constructed out of stainless steel
  • Glass bead finish
  • Large vent openings to increase steam/heat penetration rate
  • Four carrying handles
  • Supply tray with backstop to help prevent items from falling off tray
  • Supply tray track for keeping supply tray level to prevent items from falling off tray

Standard Sizes:


  • 12" dia. x 24" long
  • 18" dia. x 30" long
  • Custom sizes available on request. CBC will custom size your sterilizing cylinder to better fit your autoclave and meet your laboratory requirements. Sometimes it's doing something simple like reducing the height of the cylinder legs so the sterilizing cylinder can better fit your autoclave shelves. Or, if we just reduce the diameter by a couple of inches, you can then fit two cylinders into your autoclave side-by-side.
Standard Sterilizing Cylinder Supply Tray with backstop to help prevent items from falling off tray.

Above: Standard Sterilizing Cylinder Supply Tray with backstop to help prevent items from falling off tray.

Stainless steel transfer carts/trolleys with lockable casters and table clamps to secure sterilizing cylinders in place and prevent accidents.

Above: Stainless steel transfer carts/trolleys with lockable casters and table clamps to secure sterilizing cylinders in place and prevent accidents.  Read more

Pictured is a 18 inch dia. x 30 inch long unwrapped Standard Sterilizing Cylinder Supply Tray with backstop to help prevent items from falling off tray.

Above: Pictured is a 18" dia. x 30" long unwrapped Standard Sterilizing Cylinder Supply Tray with backstop to help prevent items from falling off tray.


Download Printable Flyer

Download a printable flyer about CBC's Sterilizing Cylinders.

Download Printable PDF

Download Printable (EU) PDF

Other CBC Sterilizing Cylinders:

CBC Autoclave Feed Sterilizing Cylinders for sterilizing rodent food for gnotobiotic animal research.
CBC Feed Sterilizing Cylinders

The CBC Stainless Steel Feed Sterilizing Cylinder provides both capacity and performance. Designed to ensure the complete sterilization of feed with minimal time and temperature to preserve the nutritional value of the feed.  Read more

12" dia. x 24" long. 18" dia. x 30" long. Custom sizes available on request.
CBC Autoclave Economy Sterilizing Cylinders for sterilizing water, bedding, cages, etc... for gnotobiotic animal research.
CBC Economy Sterilizing Cylinders

Sterilizing cylinder is constructed out of stainless steel. 3 layers of DW4 filter media. Supply tray. Stainless steel clamp. Large vent openings to increase steam/heat penetration rate.  Read more

Custom sizes available on request. Competitively priced!
Pictured is a CBC Patent Clamp being used to connect a Standard Sterilizing Cylinder to a transfer sleeve.

Above: Pictured is a CBC Patent Clamp being used to connect a Standard Sterilizing Cylinder to a transfer sleeve and the transfer sleeve to a transfer port.

Accessories and Components:

Precut filter media for Sterilizing cylinders and filters.
Pre-cut Filter Media

Save Material. Save Time.  Read more

DW4 filter media is precut to width to fit sterilizing cylinders and isolator filters.
Mylar film in rolls and precut disc shapes to cover open end of sterilizing cylinders and filter stands before autoclaving. Precut mylar discs save time!
Mylar Film

Save Material. Save Time.  Read more

Mylar film in rolls and precut disc shapes to cover open end of sterilizing cylinders and filter stands before autoclaving. Precut mylar discs save time!
Vinyl Tape.
Vinyl Tape

1" wide. 36 yards.  Read more

For wrapping filter media around sterilizing cylinders and filters.
Mylar Tape.
Mylar Tape

1" wide. 36 yards.  Read more

For attaching mylar film to sterilizing cylinders before autoclaving.
Original lap-seam seal flexible film, germfree isolator.
Manufacturing high quality, flexible film isolators for universities, researchers and germ-free animal producers since 1978.
CBC Transfer Port Caps are made with 20 mil. vinyl and are available in standard diameters and various depths.

Pictured above is a Standard 18" (diameter) x 30" Autoclave Sterilizing Cylinder (with optional support collar) fully wrapped with filter media.

(4) Four carrying handles

Constructed out of stainless steel with a glass bead finish.

Send Us a Message


608.273.9661
810 Stewart Street, Madison, Wisconsin 53713
info@cbclean.com

Email CBC.
© 2011-2022 Class Biologically Clean, Ltd. - Madison, Wisconsin - All rights reserved

® CBC is a Registered Trademark of Class Biologically Clean, Ltd.


Flexible Film Isolators, Softwall Cleanrooms, Containment Units and Accessories for Controlled Research Environments.