Helps Make Your Lab Compliant With Enhanced Double Containment BSL Requirements
Laminar Airflow Containment Units
CBC Laminar Airflow Containment Units
CBC Negative Pressure, Laminar Airflow Containment Units Can Help Make Your Lab Compliant With Enhanced Double Containment BSL Requirements
Made with durable polypropylene.
3-Door Entry Laminar Airflow Containment Unit
Negative Pressure
For enhanced double containment BSL requirements.
Make Your Lab Compliant With Enhanced Double Containment BSL Requirements
Upgrade your existing laboratory infrastructure to accommodate higher BSL level requirements by adding the extra security offered by CBC containment units, small, totally enclosed flexible film cleanrooms and negative pressure laminar flow containment units. Custom sizes to meet your exact lab requirements.
Features:
- System is run under negative pressure.
- HEPA outlet filtration system (Two exhaust filters/blowers)
- Plastic strip doors.
- Durable 20 mil. polyurethane for sidewalls and ceiling.
- Lap Seam construction.
- Resealable snap loops for easy assembly and disassembly.
- 1 1/2" anodized aluminum tubing used for frame.
- Can add wheels to make it portable.
- Custom sizes to meet lab requirments.
Electrical Requirements:
- 120 volts.
- 60 Hz.
Other Viewpoints:
The CBC Difference
The CBC difference includes our original lap-seam sealing process and the use of 20 mil. polyurethane material that is almost indestructible and helps ensure against contamination due to accidental puncture or tear.
CBC uses a highly durable "lap seam" seal for the majority of our seams, and an even superior "cut/weld/strip seam" seal for high risk areas. Because your reputation, research or production should not risk being compromised! (See, "Pull Test" and "Puncture Demonstration" videos below.)
The CBC Lap-Seal Seam "Pull" Test
Single Seam Seal vs. CBC Lap Seal Seam Read more
Because your reputation, research or production should not risk being compromised!
20 mil. Polyurethane Puncture Demonstration
CBC's 20 mil. polyurethane material is almost indestructible and helps ensure against contamination due to accidental puncture or tear. Read more
Because your reputation, research or production should not risk being compromised!
Other CBC Cleanrooms and Containment Units:

Flexible Film Cleanrooms
Can be maintained at all levels of control, from conventional to SPF (Specific pathogen-free). Not a laminar airflow design. Completely enclosed. Read more
Positive Pressure

Containment Units
Containment units are designed to protect workers and surrounding environment. Not a laminar airflow design. Completely enclosed Read more
Negative Pressure

Protecting Both Research and Researchers
Animal Research Gnotobiotic Isolators | Bio/Pharmaceutical Barrier & Containment Isolators
608.273.9661
●
810 Stewart Street, Madison, Wisconsin 53713
●
info@cbclean.com
© 2011-2022 Class Biologically Clean, Ltd. - Madison, Wisconsin - All rights reserved
® CBC is a Registered Trademark of Class Biologically Clean, Ltd.